The following points shall be checked:
Is the flow sensor mounted in the correct position and with the correct flow direction?
Does the temperature sensor fit correctly into the pocket (pockets shorter than 140 mm shall be
marked "EN 1434" or dimensions checked)?
Are the temperature sensors correctly installed?
Is the heat meter installed at a safe distance from sources of electromagnetic interference (switchgear,
electric motors,fluorescent lights)?
Where called for,has the heat meter been correctly earthed?
Are the accessories correctly installed according to the installation instructions of the supplier and
operator?
Is the heat meter seen to be functioning when the heating system starts operating?
一定要检查以下几个要点:
1 流量传感器安装位置及其流向是否正确?
2.温度传感器是否正确地装入了凹槽?(凹槽如果小于140毫米的话,需要注明“EN1434”或者进行尺寸检查)
3.温度传感器安装是否正确?
4.热量表是否安装在一些电磁干扰源(开关设备、电动装置、荧光灯等)的安全距离之外?
5.是否在需要的地方,将热量表正确地埋入地下?
6.附件是否按照厂商和操作员的说明指导进行正确地安装?
7.加热系统运作时,能否观察到热量表的运作?